Search

XVS classroom setting
  • XVS classroom setting
  • Protector XVS Ventilation Stations
  • 2' XVS with model standard ht
  • XVS with  model tall
  • 3' XVS standard height with model
  • 4 ft with model standard height
  • XVS 4 ft with model tall
  • 8' XVS with waste chute

Protector XVS Ventilation Stations

Protector XVS Ventilation Stations may be used as light duty fume hoods, science classroom work stations, solvent cleaning work bays, weighing stations or for pathology and cytology. With glass tops and sides and low profiles, they are well suited for educational settings. Patented (U.S. Patent No. 6,461,233) features including the Clean-Sweep air foil and zone-perforated rear baffle maximize containment.

Protector XVS Ventilation Stations may be ducted to the outside or connected to the FilterMate Portable Exhauster for HEPA and/or Carbon Filtered exhaust back into the laboratory.

Use Our Product Selection Tools

Scoutâ„¢ Lab Equipment Selector

Let Scout lead you to the right laboratory hood or sample prep equipment for your application.

These low profile benchtop enclosures have clear sides, top and sash for light duty fume hood use or classroom demonstrations.



Filter these products

Showing 1 - 15 of 15 Results

2' Protector XVS Ventilation Station
2' XVS with model standard ht

Catalog # 4862010

  • Nominal Width: 2'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
2' Protector XVS Ventilation Station

Catalog # 4862030

  • Nominal Width: 2'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
3' Protector XVS Ventilation Station
3' XVS standard height with model

Catalog # 4863010

  • Nominal Width: 3'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
3' Protector XVS Ventilation Station
3' XVS Tall

Catalog # 4863030

  • Nominal Width: 3'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
4' Protector XVS Ventilation Station
4 ft with model standard height

Catalog # 4864010

  • Nominal Width: 4'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
4' Protector XVS Ventilation Station
4' XVS Tall

Catalog # 4864030

  • Nominal Width: 4'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
5' Protector XVS Ventilation Station
4 ft with model standard height

Catalog # 4865010

  • Nominal Width: 5'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
5' Protector XVS Ventilation Station
4' XVS Tall

Catalog # 4865030

  • Nominal Width: 5'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
5' Protector XVS Ventilation Station
8' XVS with waste chute

Catalog # 4865060

  • Nominal Width: 5'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
6' Protector XVS Ventilation Station
4 ft with model standard height

Catalog # 4866010

  • Nominal Width: 6'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
6' Protector XVS Ventilation Station
4' XVS Tall

Catalog # 4866030

  • Nominal Width: 6'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
6' Protector XVS Ventilation Station
8' XVS with waste chute

Catalog # 4866060

  • Nominal Width: 6'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
8' Protector XVS Ventilation Station
4 ft with model standard height

Catalog # 4868010

  • Nominal Width: 8'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
8' Protector XVS Ventilation Station
4' XVS Tall

Catalog # 4868030

  • Nominal Width: 8'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop
8' Protector XVS Ventilation Station
8' XVS with waste chute

Catalog # 4868060

  • Nominal Width: 8'
  • Region: Not Applicable
  • Blower Requirements: Remote blower required
  • Style: Benchtop

Fume Hoods Overview 2013

Literature & Resources

  • Brochures

    • Educational Fume Hoods & Enclosures Catalog

      This catalog contains ordering information and dimensional data on Protector ClassMate Laboratory Hoods, Basic Laboratory Hoods, Fiberglass 30 Laboratory Hoods, Protector XVS Ventilation Stations, Protector Demonstration Hoods, FilterMate Portable Exhausters and Canopy Hoods. The catalog also provides ordering information on work surfaces and accessories for these ventilation products. This is Labconco literature code 2-88.

      View Files

    • Ductless Carbon-Filtered Enclosures Catalog

      This catalog contains ordering information on Paramount Ductless Enclosures, Fume Adsorbers, Protector XVS Ventilation Stations, Protector Work Stations, Protector Demonstration Hoods, FilterMate Portable Exhausters and accessories. This is Labconco literature code 3-04.

      View Files

  • User's Manuals

    • XPert Balance Enclosures and Protector XVS Ventilation Stations Manual

      For catalog numbers: 3930200, 3930201, 3930202, 3930221, 3930222, 3930230, 3930231, 3930232, 3030241, 3930242, 3930300, 3930301, 3930302, 3930321, 3930322, 3930330, 3930331, 3930332, 3030341, 3930342, 3930400, 3930401, 3930402, 3930421, 3930422, 3930430, 3930431, 3930432, 3030441, 3930442, 3971500, 3971501, 3971502, 3971521, 3971522, 3971530, 3971531, 3971532, 3971541, 3971542, 3971560, 3971561, 3971562, 3971571, 3971572, 3971600, 3971601, 3971602, 3971621, 3971622, 3971630, 3971631, 3971632, 3971641, 3971642, 3971660, 3971661, 3971662, 3971671, 3971672, 3971800, 3971801, 3971802, 3971821, 3971822, 3971830, 3971831, 3971832, 3971841, 3971842, 3971860, 3971861, 3971862, 3971871, 3971872, 4862010, 4862011, 4862012, 4862021, 4862022, 4862030, 4862031, 4862032, 4862041, 4862042, 4863010, 4863011, 4863012, 4863021, 4863022, 4863030, 4863031, 4863032, 4863041, 4863042, 4864010, 4864011, 4864012, 4864021, 4864022, 4864030, 4864031, 4864032, 4864041, 4864042, 4865010, 4865011, 4865012, 4865021, 4865022, 4865060, 4865

      View Files

  • 3-Part Specs

    • Protector XVS Ventilation Stations Specifications

      View Files

  • CAD Drawings

    • 3' Protector XVS Ventilation Station CAD

      CAD drawing for catalog number 4863030

      View Files

    • 4' Protector XVS Ventilation Station Bottom Exhaust CAD

      View Files

    • Protector XVS Ventilation Station (2 feet) CAD

      Top Exhaust.  Catalog number 4862010

      View Files

    • Protector XVS Ventilation Station (2 feet) CAD

      Bottom Exhaust Catalog number 4862010

      View Files

    • Protector XVS Ventilation Station (3 feet) CAD

      Top Exhaust Catalog number 4863010

      View Files

    • Protector XVS Ventilation Station (3 feet) CAD

      Bottom Exhaust Catalog number 4863010

      View Files

    • Protector XVS Ventilation Station (4 feet) CAD

      Top Exhaust Catalog number 4864010

      View Files

    • Protector XVS Ventilation Station (4 feet) CAD

      Bottom Exhaust Catalog number 4864010

      View Files

    • Protector XVS Ventilation Stations SketchUp 3D CAD

      In order to view 3D CAD Drawings, download and install the Google Sketchup Viewer from sketchup.google.com The application will prompt you through the installation process.

      View Files

Related Products

Guardian Digital Airflow Monitor

Airflow Monitors

These monitors, used for a variety of fume hoods, enclosures and glove boxes, sense airflow and alert the user to low airflow conditions.

Protector Standard Storage Base Cabinet with Dual Doors

Base Cabinets

Base Cabinets provide support for the full line of benchtop Labconco fume hoods and other enclosures and may be mixed or matched so that total width equals the width of the hood.

Ducting Supplies

Ductwork and Blower Accessories

Labconco offers a full line of ductwork, filter packs and transition pieces to complete your exhaust system.

Fume Hood Accessories

Fume Hood Accessories

Labconco offers a complete line of accessories to customize your Protector, Basic or Fiberglass 30 Laboratory Hood.

Remote Blowers & Exhausters

Remote blowers, designed for roof-mounting, provide airflow for fume hoods and other enclosures. Exhausters, designed for ductless applications, filter the air before returning it to the lab.

SpillStopper Work Surface

Work Surfaces

Labconco offers dished and flat solid epoxy and flat stainless steel work surfaces that work with a number of Labconco fume hoods and enclosures.